www.lighttoolsupply.com

Monday, May 13, 2013

Baileigh Plate Shear SH-120250-HD


Order at Light Tool Supply
http://www.lighttoolsupply.com

Baileigh Plate Shear SH-120250-HD 
#Baileigh Plate Shear SH-120250-HD

Features:

At 18 strokes a minute the SH-120250-HD from Baileigh Industrial is a must have in any production environment that shears ¼” mild steel.  The SH-120250-HD plate shear can cut ¼” mild steel over its entire 120” length.  For even more production the SH-120250-HD features an NC controller for programming of the back gauge.  This programmer is accurate to =/- .01mm and can hold up to 100 programs.  Convenient rolling tables mounted on the front of the machine help with loading of materials.  Gap is easily adjusted via hand wheels.  Another nice feature is the shadow line postioner to help with placement of material.

Since the SH-120250-HD plate shear is built to last, Baileigh Industrial uses only the best quality components, Schneider electrical, Rexroth hydraulic systems, and NOK seals from Japan.  The massive frame of the SH-120250-HD is all integrated and fully welded to eliminate vibrations commonly found on other models.  By eliminating vibrations, it is eliminating any stress that can occur during the cutting process.

Specifications:
Thickness (mild steel) .250"
Max. Material Thickness (Stainless Steel) .157"
Blade Rake Angle .5° - 1.5°
Blade Clearance Manual Hand Wheel
Back Gauge Length 25.6" (motorized)
Shear Length 120"
Motor 15 hp
Power Requirements 220V 3-Phase / 60 Hertz
Shipping Weight 14,560 lbs.
Shipping Dimensions 154" x 64" x 77"

Mechanix Wear The Original 0.5mm Glove, High Dexterity

Order #MechanixWear Gloves at Light Tool Supply
http://www.lighttoolsupply.com/





Mechanix Wear The Original 0.5mm Glove, High Dexterity
Mechanix Wear The Original 0.5mm Glove, High Dexterity

Features:

  • Ultra Feel: 0.5mm synthetic leather form fits hand for precision work.
  • Index Finger: 0.5mm synthetic leather wraps top of finger for increased dexterity and protection.
  • When you need the tactile control of bare hands while still wearing gloves, get the Original® 0.5mm.
  • Our most dexterous glove, the Original®  0.5mm features a new more supple 0.5mm synthetic leather palm, fingertips and thumb, allowing for superior feel and pinpoint precision.
  • Non-lined, four-way stretch spandex finger gussets and thumb panel and stretch Lycra finger panels provide ultimate flexibility.

Thursday, May 9, 2013

#MahrFederal

Order Mahr Gages at Light Tool Supply http://www.lighttoolsupply.com

“SQUEEZE” GAGING
George Schuetz, Mahr Federal Inc.
 Machinists working strictly in metal-working shops do not have many occasions to gage the thickness of soft materials.  But many of our readers work in supporting roles, helping to build or maintain the machines that produce textiles, plastic films, paper and other products that are compressible.  Even readers who work only with metals should realize they are not alone in their concern for accuracy:  the shirt on your back, the newspaper you read this morning and the garbage bag you tossed it in, were all produced to exacting thickness tolerances.
 Differences in gaging pressure translate readily into differences in the degree to which the sensitive contact compresses or penetrates the material being gaged.  It is, therefore, essential to use a standardized method when measuring the thickness of compressible materials.  Every industry and every kind of material has its own standards, most of which have been established by the American Society for Testing Materials or by Underwriters’ Laboratories.  These standards specify the size of the reference table and the measuring contact (or foot), the dial gradations, and the amount of force to be used.  (Gaging force is controlled by a weight, rather than with the springs found in most dial indicators, to ensure consistency of compression).  Such standards make purchasing decisions quite straightforward:  often, you need only specify which ASTM standard you wish to meet.
 Assuming you have the right gage for your material, making accurate measurements of compressible materials is not difficult if you follow a few basic guidelines:
The Anvils Must be Parallel

 If they are not, they will compress the material at an edge rather than across a flat surface.  To check for parallelism, close the contacts and try to shine a flashlight through them.  Parallel contacts allow no light to shine through; any lack of parallelism is readily apparent down to about 0.0001” (2um).  Check front to back, and side to side.
 It is difficult to hold larger contacts -- say those above 1/2” x 1/2” (12mm x 12mm)--in alignment with the light source.  And the visual method may fail to reveal problems such as an upper foot with a worn center or a chipped edge.
 If you need more accuracy or if visual inspection reveals a lack of parallelism and you want to measure it, use this method:  Place a precision wire of 0.010” or 0.020” (.2mm or .5mm) diameter under the front edge of the upper foot, and zero the indicator.  Then retract the contact, place this “master” under the rear edge, and repeat the measurement, noting the variation.  Repeat for left and right sides also.
 Some gages have machine screws to adjust the reference table into parallel with the upper foot.  On those gages that do not, the common solution is to file down either the boss that holds the indicator to the frame, or the shoulder against which the reference table support is clamped.  Easy does it!


Make Sure Contacts Are Not Contaminated
 This is a common source of error.  As in any gaging procedure, the contacts must be kept clean of dirt, lint or hair.  When measuring materials such as polyethylene film, which may have been in liquid form only minutes before, beware of the buildup of chemical deposits on the contacts.  As with any textile product, frequently clean lint off the contacts.
Check for Gage Repeatability By Checking Several Points on the Surface of a Known, Consistent Sample
 Most gages for thin materials do not need to be mastered.  Simply “zero” the gage against the reference table.  To avoid having to count dial revolutions when measuring thicker materials like acoustic tiles or carpet, use a gage block to set the zero at the nominal dimension of the material.
 If a gage reads “under”, the problem is most likely a lack of parallelism.  If it reads “over”, dirt is probably the culprit.  Of course, other factors common to all gaging, such as friction in the mechanism or a loose fixture, can also be at fault.
                              

Wednesday, May 8, 2013

Hoppy Photometric Headlight Aimer VISION 100

Hoppy Photometric Headlight Aimer VISION 100

Hoppy Photometric Headlight Aimer VISION 100

The Hoppy Vision 100 Photometric Headlight Aimer has received the prestigious Innovation Tools Award sponsored by Professional Tool and Equipment News . It was selected by a panel of shop owners and technicians all of whom are Certified Master Technicians. The criteria for the selection include uniqueness, improvement over existing products, time saving ability and cost.

The Hoppy Vision 100 Photometric Headlamp Aimer is the result of a concentrated effort by Hoppy to develop a state of the art photometric aimer that is affordable, easy to use and will aim all D.O.T approved headlamps.

The Vision 100 is approved for use in all states and Provinces. It is also approved for all state Inspection programs including Maryland and Virginia.

Features:
  • LCD digital display gives simple, readable step by step aiming instructions.
  • Uses laser technology to square the aimer to the vehicle (no aiming visor needed).
  • The front centering cover uses photo diodes to accurately locate the optical center of lamp.
  • The operator is prompted with arrows on the LCD display which direction to move the aimer.
  • After there is Two XXft.s on the screen the aimer has found optical center of lamp (no light intensity meter needed).
  • Uses rechargeable Ni-Cad batteries.
  • Includes: Floor Track and Battery Charger.
Specifications:
Field of View:  ± 49in. V x ± 65in. H @ 25ft.
Candela: 1,000 – 100,000 candela
Temperature: 32 – 110 degrees F
Storage Temperature: 0 – 120 degrees F
Humidity: Non-condensing
Update Speed: 1 update / sec (maximum)
Accuracy: 4in. @25ft.
Repeatability: 1in. @ 25ft.
Power: Ni-Cad battery pack & 9 VDC Wall Charger
Voltage Input: 7.2 – 9.0 VDC
Battery Life (continuous): ± 4.25 hours
Headlamp Styles: US Low Beam, US High Beam, Fog Lamp
Aim Algorithms: Fractional Zone Aim (FZA), Hot Zone Aim (HZA)
Floor Slope Compensation: Adjustable ± 2O


TMX #LiveCenters, Precision Accuracy 0.0002"


TMX Live Centers, Precision Accuracy 0.0002"
Order here http://www.lighttoolsupply.com

Features:

• Machined from one piece of forging.
• Hardened and precisely ground.
• Spindle is made of high quality Alloy Steel, heat treated to RC 60-62.
• Centers are provided with three selected heavy duty precision bearings.
• Bearings are protected against dust and coolant.






TMX Live Centers, Precision Accuracy 0.0002

Thursday, May 2, 2013

Universal Stand for Mahr/Federal Pocket Surf






Universal Stand for Mahr/Federal Pocket Surf


Features:
The EAS 2426 Universal Stand is a heavy duty, fully adjustable, multi-position comparator stand for staging the PocketSurf unit in any position relative to the workpiece surface to be measured. The stand will accommodate workpieces ranging in height from flush with the stand’s work surface up to 8.4"/ 215mm high, and can be used with or without additional workpiece fixturing.

The probe can be in its 90°,180° “Extended” or 270° positions. The stand’s 360° Column Clamp and Bracket can be positioned anywhere vertically and radially on the column, permitting the stand to be used as a height stand on a surface plate or other suitable work surface to measure workpieces positioned adjacent to it.
 

Wednesday, May 1, 2013

EDGE Mini Pro Tram



EDGE Mini Pro Tram



EDGE Mini Pro Tram
The Mini Pro Tram by Edge Technology has all the same great features of the full size Pro Tram but in a smaller package. The unit is perfectly sized for bench-top and mini-mill machines.

Features:

  • Square the head of a milling machine and milling vises quickly and easily
  • Simply lower unit to table and adjust the head until both indicators read the same
  • Can be used with a sine bar or sine plate to adjust the head to precise angles
  • Calibration procedure accounts for any error introduced by worn collets
  • Guaranteed to be equal to or better than any other tramming method or spindle squaring device available.
  • Indicator graduation 0.001" & repeatability of 0.0002”
  • Includes calibration gage and padded case